EUROLAB
epa-1664-determination-of-mercury-in-waste
RoHS Substance Testing ASTM D5511 Analysis of Brominated Flame RetardantsASTM D5551 Brominated Flame Retardants QuantificationASTM D6474 Bromine Content DeterminationASTM D6829 Determination of Halogens in ElectronicsASTM D7135 Analysis of Restricted SubstancesASTM E1681 Screening for RoHS ComplianceASTM F2617 Screening for Hazardous Substances in ElectronicsASTM F2619 Analysis of Lead in ElectronicsASTM F2621 Flame Retardant Content AnalysisEN 50581 Documentation of RoHS ComplianceEN 50581-1 RoHS Material Declaration VerificationEN 50581-2 Compliance Documentation ReviewEN 50581-3 Material Traceability for RoHSEN 50581-4 RoHS Documentation AuditEN 50581-5 RoHS Material Compliance AssessmentEN 50581-6 Compliance Strategy for RoHSEN 50581-7 RoHS Compliance Report PreparationEN 62321-1 Overview of Analytical Methods for RoHSEPA 3050B Sample Preparation for RoHS TestingEPA 6010D ICP-AES for RoHS ElementsEPA 7473 Mercury Analysis by Thermal DecompositionEPA Method 3052 Microwave Assisted Acid Digestion for RoHSIEC 62321-1 Determination of RoHS Restricted SubstancesIEC 62321-10 Determination of Antimony in E-WasteIEC 62321-11 Testing for Beryllium ContentIEC 62321-12 Determination of Phthalates in PolymersIEC 62321-13 Measurement of Cadmium in PlasticsIEC 62321-14 Testing for Chromium VI in ElectronicsIEC 62321-15 Determination of Mercury in PolymersIEC 62321-16 Phthalate Content AnalysisIEC 62321-17 Quantification of Lead in SolderIEC 62321-18 Analysis of RoHS Substances in MetalsIEC 62321-19 Determination of Antimony in ElectronicsIEC 62321-2 Cadmium Content AnalysisIEC 62321-20 Testing for Polybrominated Flame RetardantsIEC 62321-21 Phthalate Ester AnalysisIEC 62321-22 Quantification of Hexavalent ChromiumIEC 62321-23 Determination of Cadmium in Electronic ComponentsIEC 62321-24 Lead Content in Electronic ComponentsIEC 62321-25 Mercury Content in PolymersIEC 62321-26 Detection of Polybrominated Diphenyl EthersIEC 62321-27 Testing for Restricted PhthalatesIEC 62321-28 Determination of Hexavalent Chromium in PlasticsIEC 62321-29 Screening for RoHS Restricted ElementsIEC 62321-3 Lead Content MeasurementIEC 62321-30 Phthalate Content VerificationIEC 62321-31 Testing for Polybrominated Flame RetardantsIEC 62321-32 Analysis of Cadmium in PlasticsIEC 62321-33 Lead and Mercury Content TestingIEC 62321-34 Testing for Phthalates in ElectronicsIEC 62321-35 Determination of Hexavalent Chromium in ElectronicsIEC 62321-36 Quantification of Brominated Flame RetardantsIEC 62321-4 Mercury QuantificationIEC 62321-5 Hexavalent Chromium TestingIEC 62321-6 Polybrominated Biphenyls (PBB) DetectionIEC 62321-7 Polybrominated Diphenyl Ethers (PBDE) AnalysisIEC 62321-8 Phthalate Esters ScreeningIEC 62321-9 Determination of Brominated Flame RetardantsISO 11890-1 Testing of Coatings for RoHS SubstancesISO 14593 Testing for Halogens in PolymersISO 16750-2 Environmental Conditions Testing for ElectronicsISO 17025 Accredited RoHS TestingISO 17294 ICP-MS for Trace Elements in E-WasteRoHS 2 Directive Verification TestingRoHS 3 Directive Compliance TestingRoHS Directive 2011/65/EU Compliance TestingRoHS Directive 2015/863 Phthalates TestingRoHS Restricted Elements CertificationRoHS Restricted Substance QuantificationRoHS Restricted Substances Limit VerificationRoHS Substance Content AuditingRoHS Substance Migration Testing

Comprehensive Guide to EPA 1664 Determination of Mercury in Waste Testing Service

Provided by Eurolab: A Laboratory Testing Expertise

Table of Contents

1. Standard-Related Information

2. Standard Requirements and Needs

3. Test Conditions and Methodology

4. Test Reporting and Documentation

5. Why This Test Should Be Performed

6. Why Eurolab Should Provide This Service

The EPA 1664 Determination of Mercury in Waste testing service is governed by various international and national standards, ensuring the accuracy and reliability of test results. The key standards applicable to this laboratory test are:

  • ISO 17294-2:2013: Selenium and mercury - Atomic absorption spectrometry - Part 2: Mercury
  • ASTM E1111-08 (2014): Standard Test Method for Mercury in Waste Materials by Cold Vapor Atomic Absorption Spectrophotometry
  • EN 14338:2005: Waste water - Determination of mercury - Flameless atomic absorption spectrometry
  • TSE EN ISO 17294-2:2013: Selenium and mercury - Atomic absorption spectrometry - Part 2: Mercury (Turkish Standard)
  • These standards specify the requirements for testing, equipment, sample preparation, measurement, and analysis. The laboratory must comply with these standards to ensure that test results are accurate and reliable.

    Standard Development Organizations

    The International Organization for Standardization (ISO) is responsible for developing international standards, while national standard development organizations, such as the American Society for Testing and Materials (ASTM), develop national standards. The European Committee for Standardization (CEN) develops European Standards, which are adopted by member countries.

    Evolution of Standards

    Standards evolve over time to reflect changes in technology, methods, and testing requirements. New standards may be developed or existing ones revised to address emerging issues, such as environmental protection and sustainability.

    Standard Numbers and Scope

    The following standard numbers and their scope are relevant to EPA 1664 Determination of Mercury in Waste testing:

  • ISO 17294-2:2013 - Specifies the method for determining mercury in waste materials using atomic absorption spectrometry.
  • ASTM E1111-08 (2014) - Provides a test method for measuring mercury in waste materials using cold vapor atomic absorption spectrophotometry.
  • Standard Compliance Requirements

    Compliance with these standards is essential to ensure that laboratory test results are reliable and accurate. Industry sectors, such as hazardous waste management, chemical manufacturing, and environmental protection, require compliance with relevant standards to maintain regulatory approval and customer confidence.

    Standard-Related Information Summary Table

    Standard Number Title Scope

    --- --- ---

  • ISO 17294-2:2013
  • Selenium and mercury - Atomic absorption spectrometry - Part 2: Mercury

    Waste materials, including hazardous waste

  • ASTM E1111-08 (2014)
  • Standard Test Method for Mercury in Waste Materials by Cold Vapor Atomic Absorption Spectrophotometry

    Waste materials, including hazardous waste

    The EPA 1664 Determination of Mercury in Waste testing service is essential to ensure the safe disposal of hazardous waste. This test detects mercury levels in waste samples, which can be toxic to humans and the environment.

    Why This Test Is Needed

  • Business and Technical Reasons: Conducting this test ensures compliance with regulatory requirements, reduces business risks associated with non-compliance, and maintains customer trust.
  • Consequences of Not Performing This Test: Failure to detect mercury levels in waste samples can result in environmental pollution, contamination of soil and water resources, and exposure to toxic chemicals.
  • Industries and Sectors

    The following industries require EPA 1664 Determination of Mercury in Waste testing:

  • Hazardous waste management
  • Chemical manufacturing
  • Environmental protection
  • Government agencies (e.g., environmental departments)
  • Quality Assurance and Control Aspects

    To ensure test results are accurate, laboratories must implement quality assurance and control measures, including:

  • Calibrating equipment regularly
  • Maintaining proper documentation and records
  • Ensuring qualified personnel perform tests
  • Risk Factors and Safety Implications

    Mercury is a toxic substance that can cause serious health effects, including neurological damage, kidney failure, and birth defects. Laboratories must handle mercury samples with care to prevent exposure.

    The EPA 1664 Determination of Mercury in Waste testing service involves several steps:

    1. Sample Preparation: Prepare the waste sample for analysis by crushing or grinding it into a fine powder.

    2. Equipment Calibration: Calibrate equipment, such as atomic absorption spectrometers, to ensure accurate measurements.

    3. Measurement and Analysis: Measure mercury levels using atomic absorption spectrometry or cold vapor atomic absorption spectrophotometry.

    Test Conditions Summary Table

    Test Condition Description

    --- ---

  • Sample preparation
  • Crushing or grinding waste samples into a fine powder

  • Equipment calibration
  • Calibrating atomic absorption spectrometers to ensure accurate measurements

    To maintain compliance with standards, laboratories must provide detailed reports of test results:

    1. Documentation: Maintain proper documentation of testing procedures, including equipment calibration records.

    2. Report Format: Provide a clear, concise report format for easy interpretation by stakeholders.

    Test Reporting Summary Table

    Report Element Description

    --- ---

  • Test result summary
  • Displaying test results in a clear and understandable manner

  • Equipment calibration records
  • Documenting equipment calibration to ensure accuracy

    EPA 1664 Determination of Mercury in Waste testing ensures the safe disposal of hazardous waste by detecting mercury levels. This test:

    1. Ensures Compliance with Regulatory Requirements: Maintains regulatory approval and reduces business risks associated with non-compliance.

    2. Maintains Customer Trust: Provides accurate and reliable results, ensuring customer trust and confidence.

    Industries and Sectors That Require This Test

    The following industries require EPA 1664 Determination of Mercury in Waste testing:

  • Hazardous waste management
  • Chemical manufacturing
  • Environmental protection
  • Government agencies (e.g., environmental departments)
  • Eurolab, as a laboratory testing expertise, provides the EPA 1664 Determination of Mercury in Waste testing service to ensure accurate and reliable results:

    1. Compliance with Standards: Ensures compliance with international and national standards.

    2. Experienced Personnel: Trained and experienced personnel perform tests to maintain accuracy.

    Eurolabs Expertise Summary Table

    Service Description

    --- ---

  • EPA 1664 Determination of Mercury in Waste testing
  • Providing accurate and reliable results

    This comprehensive guide highlights the importance of EPA 1664 Determination of Mercury in Waste testing, emphasizing its role in ensuring the safe disposal of hazardous waste.

    Need help or have a question?
    Contact us for prompt assistance and solutions.

    Latest News

    View all

    JOIN US
    Want to make a difference?

    Careers