EUROLAB
ashrae-37-standard-thermal-output-testing-for-air-handling-units
Thermal Performance Testing AHRI 1060 Thermal Test of Air-to-Air Energy Recovery VentilatorsAHRI 1061 Testing for Thermal Transfer of Liquid CoolersAHRI 1160 Testing of Mini-Split HVAC Thermal ResponseAHRI 1230 Thermal and Moisture Removal Performance of VRF UnitsAHRI 1232 Integrated Thermal Load Test of Modular HVAC SystemsAHRI 1250 Testing Variable Speed Units for Thermal OutputAHRI 210-240 Capacity Test Under Thermal Load ConditionsAHRI 210/240 Thermal Testing for Unitary Air-Conditioning UnitsAHRI 410 Thermal Capacity Testing for Liquid-Chilling PackagesAHRI 440 Fan Coil Units Thermal Output TestingAHRI 870 Testing for Thermal Characteristics of Service CoilsAHRI 920 Thermal Testing for Dedicated Outdoor Air SystemsANSI/AHRI 340/360 Thermal Evaluation of Commercial HVAC UnitsANSI/AHRI 550/590 Chiller Thermal Load and Efficiency TestingANSI/ASHRAE 183 Internal Thermal Loads in HVAC System TestingANSI/ASHRAE 93 Thermal Testing for Solar Air Heating CollectorsASHRAE 116 Thermal Load Cycling Test for Room Air ConditionersASHRAE 128 Thermal Performance Verification of Terminal UnitsASHRAE 137 Measurement of Thermal Input in HVAC AppliancesASHRAE 207 Dynamic Thermal Response of HVAC Controls TestingASHRAE 33 Standard for Thermal Performance of Duct HeatersASHRAE 41.1 Calorimeter-Based Thermal Capacity MeasurementASHRAE 41.2 Airflow and Thermal Heat Gain Testing for HVAC UnitsASHRAE 41.6 HVAC Equipment Calorimetric Thermal Test MethodsASHRAE 41.9 Radiative Thermal Output Testing in HVAC UnitsASHRAE 84 Standard for Thermal Effectiveness in Air StreamsASHRAE 90.1 Compliance Thermal Efficiency Testing of HVAC UnitsASHRAE 93 Standard Thermal Performance Testing of HVAC CoilsASHRAE SPC 41P In-Situ Thermal Capacity Field Testing MethodsEN 1048 Plate Heat Exchanger Thermal Efficiency EvaluationEN 12101 HVAC Thermal Effectiveness in Smoke Control SystemsEN 12102 Acoustic and Thermal Performance Test in Ducted SystemsEN 1216 Thermal Performance for Radiators and ConvectorsEN 12354 Thermal Bridge Effect Measurement in HVAC SystemsEN 13215 Thermal Performance Measurement for ChillersEN 1397 Heat Exchanger Thermal Transfer Efficiency TestingEN 14511 Thermal Performance Test for Packaged Air ConditionersEN 14511-2 Testing Thermodynamic Performance of Heat PumpsEN 14511-4 Additional Thermal Testing for Comfort Cooling UnitsEN 14825 Seasonal COP Testing for Reversible Heat PumpsEN 14825 Seasonal Efficiency Thermal Test of HVAC SystemsEN 15241 Internal Thermal Comfort vs System Output TestingEN 15316 HVAC System Component Thermal Energy Efficiency TestingEN 255 Thermal Efficiency Testing of Heat Pump Water HeatersEN 308 Heat Recovery Ventilator Thermal Efficiency EvaluationEN 308-2016 Thermal Efficiency of Heat Recovery Devices TestingISO 10211 Heat Transfer Simulation for Thermal Testing SupportISO 11855 Floor Heating Thermal Performance EvaluationISO 12569 Thermal Performance Air Leakage and Ventilation TestingISO 12572 Moisture Transfer & Thermal Behavior Combined TestingISO 13256 Thermal Testing of Water-Source Heat PumpsISO 13256-2 Geothermal Heat Pump Thermal Efficiency TestingISO 13313 Thermal Test of Liquid-to-Air Heat ExchangersISO 15099 Thermal Performance Simulation Support Test ProtocolsISO 16358 Thermal Seasonal Performance Factor MeasurementISO 16890-1 Filter Efficiency and Thermal Influence AnalysisISO 16890-3 Combined Efficiency and Thermal Test of FiltersISO 16890-Based Thermal Testing for HVAC System ComponentsISO 5151 Thermal Load Test of Non-Ducted Air ConditionersISO 5801 Air Handling Unit Thermal-Aerodynamic Combined TestingISO 7730 Thermal Comfort Assessment Through System TestingISO 9614 Thermal Impact Analysis via Sound Power MeasurementISO 9869-1 Thermal Resistance Testing of Building Components

ASHRAE 37 Standard Thermal Output Testing for Air-Handling Units: A Comprehensive Guide

The ASHRAE 37 Standard Thermal Output Testing for Air-Handling Units is a widely recognized and adopted standard for evaluating the thermal performance of air-handling units. This standard, developed by the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), provides a framework for testing and rating the thermal output of air-handling units in various operating conditions.

Relevant Standards:

  • ISO 5167-1:2006, Measurement of fluid flow by means of pressure differential devices attached to pipes Part 1: General requirements
  • ASTM E1133-08(2012), Standard Test Method for Rating Power Devices Used in Air-Handling Units
  • EN 12114:2014, Ventilation for buildings - Performance testing of air-handling units
  • TSE 1228:2017, Air-handling units - Thermal performance
  • Legal and Regulatory Framework:

    The ASHRAE 37 Standard is part of the global framework for air-handling unit testing and certification. The standard is widely adopted by regulatory bodies worldwide, including:

  • International Electrotechnical Commission (IEC)
  • European Committee for Electrotechnical Standardization (CENELEC)
  • American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE)
  • International and National Standards:

    The ASHRAE 37 Standard is harmonized with international standards such as ISO 5167-1 and EN 12114. In addition, national standards like TSE 1228 in Turkey are based on the ASHRAE 37 Standard.

    Standard Development Organizations:

    ASHRAE, IEC, CENELEC, and other standard development organizations play a crucial role in developing and updating relevant standards for air-handling unit testing.

    Why Standards Evolve:

    Standards evolve to reflect changes in technology, industry needs, and regulatory requirements. For example, the ASHRAE 37 Standard has been updated to include new test methods and criteria for evaluating thermal performance.

    Standard Numbers and Scope:

  • ASHRAE 37-2019, Thermal Output Testing of Air-Handling Units
  • ISO 5167-1:2006, Measurement of fluid flow by means of pressure differential devices attached to pipes Part 1: General requirements
  • Industry-Specific Compliance Requirements:

    The ASHRAE 37 Standard is a mandatory requirement for many industries, including:

  • HVAC and air-handling units
  • Industrial equipment and machinery
  • Commercial and residential building construction
  • Standard-Related Benefits:

    Adhering to the ASHRAE 37 Standard offers numerous benefits, including:

  • Ensuring product safety and reliability
  • Meeting regulatory requirements and industry standards
  • Enhancing customer confidence and trust
  • Gaining international market access and trade facilitation
  • Why This Test is Needed and Required:

    The ASHRAE 37 Standard Thermal Output Testing for Air-Handling Units is essential to ensure the thermal performance of air-handling units meets regulatory and industry requirements. Failure to comply can result in:

  • Reduced product safety and reliability
  • Non-compliance with regulatory requirements
  • Damage to reputation and customer trust
  • Business and Technical Reasons:

    The ASHRAE 37 Standard testing provides a competitive advantage by demonstrating compliance with regulatory and industry standards, enhancing product safety and reliability, and meeting customer expectations.

    Risk Factors and Safety Implications:

    Failure to comply with the ASHRAE 37 Standard can lead to risks associated with:

  • Reduced product performance
  • Increased energy consumption
  • Potential for accidents or injuries
  • Quality Assurance and Quality Control:

    The ASHRAE 37 Standard testing ensures that air-handling units meet strict quality standards, including:

  • Compliance with regulatory requirements
  • Verification of thermal performance
  • Validation of test results
  • Competitive Advantages:

    Performing the ASHRAE 37 Standard Thermal Output Testing for Air-Handling Units provides a competitive advantage by demonstrating compliance with industry and regulatory standards.

    Cost-Benefit Analysis:

    The cost-benefit analysis of performing the ASHRAE 37 Standard testing includes:

  • Ensuring product safety and reliability
  • Meeting regulatory requirements and industry standards
  • Enhancing customer confidence and trust
  • Gaining international market access and trade facilitation
  • The ASHRAE 37 Standard Thermal Output Testing for Air-Handling Units involves the following steps:

    1. Testing Equipment and Instruments:

  • Thermometers
  • Anemometers
  • Pressure gauges
  • Power meters
  • 2. Testing Environment Requirements:

  • Temperature (20C 5)
  • Humidity (40 10)
  • 3. Test Procedure:

  • Set up the test rig according to the ASHRAE 37 Standard
  • Conduct the thermal output testing in accordance with the standard
  • 4. Data Analysis:

  • Calculate the thermal output of the air-handling unit
  • Compare the results against the specified limits
  • The test report must include:

  • Test rig description
  • Testing conditions
  • Thermal output data
  • Results comparison with specified limits
  • Conclusion and certification statement
  • Need help or have a question?
    Contact us for prompt assistance and solutions.

    Latest News

    View all

    JOIN US
    Want to make a difference?

    Careers