EUROLAB
en-459-2-test-methods-for-building-lime
Cement and Lime Analysis AASHTO M240 Standard Specification for Lime for Soil StabilizationAASHTO M85 Portland Cement SpecificationAASHTO T105 Fineness of Cement by Air PermeabilityAASHTO T106 Density of Hydraulic CementAASHTO T114 Setting Time of Hydraulic CementAASHTO T152 Chemical Analysis of Hydraulic CementASTM C1074 Estimating Concrete Strength by Maturity MethodASTM C1107 Specification for Packaged Dry, Hydraulic-Cement GroutASTM C114 Chemical Analysis of Hydraulic CementASTM C114 Standard Chemical Analysis of Cementitious MaterialsASTM C1146 Testing Blended Hydraulic CementsASTM C1157 Performance Specification for Hydraulic CementASTM C1158 Testing Pozzolanic Reactivity of CementASTM C1240 Testing Silica Fume for Use in Cementitious MaterialsASTM C1364 Testing Pozzolanic Cementitious MaterialsASTM C150 Specification for Portland CementASTM C1506 Chemical Composition of Portland Cement by XRFASTM C1510 Evaluation of Cement Clinker for SoundnessASTM C1517 Specification for Hydrated Lime for Masonry PurposesASTM C1602 Sampling and Testing of Hydraulic CementASTM C1608 Chemical Analysis of Gypsum and LimeASTM C1679 Testing Early-Age Shrinkage of Cementitious MixturesASTM C1709 Testing Pozzolanic Materials for Use in CementASTM C185 Air Content of Hydraulic CementASTM C185 Determination of Air Content in Cement PastesASTM C187 Determination of Normal Consistency of CementASTM C187 Normal Consistency of Hydraulic CementASTM C191 Time of Setting of Hydraulic Cement by Vicat NeedleASTM C204 Fineness of Hydraulic Cement by Air PermeabilityASTM C311 Sampling and Testing Fly Ash or Raw or Calcined Natural PozzolansASTM C430 Fineness of Hydraulic Cement by Wet SievingASTM C977 Specification for Quicklime for Treatment of WaterBS EN 196-2 Cement Chemical AnalysisBS EN 196-3 Cement Setting Times and SoundnessBS EN 450-1 Fly Ash for Use in ConcreteBS EN 459 Lime SpecificationsBS EN 459-2 Test Methods for Building LimeEN 196-1 Determination of Strength of CementEN 196-11 Determination of Alkali Content in CementEN 196-2 Methods of Testing Cement - Chemical AnalysisEN 196-3 Determination of Setting Times and SoundnessEN 196-6 Determination of FinenessEN 196-7 Air Content of CementEN 197-1 Composition, Specifications and Conformity Criteria for Common CementsEN 450-1 Fly Ash for Concrete - SpecificationsEN 451-1 Determination of Loss on Ignition in CementEN 459-1 Building Lime - Definitions, Specifications and Conformity CriteriaEPA SW-846 Method 6010 Metal Analysis in CementEPA SW-846 Test Methods for Cement ContaminantsISO 10426 Testing Hydrated Lime for Use in MortarsISO 10665 Chemical Analysis of Hydraulic CementISO 13194 Determination of Chloride Content in CementISO 13194 Determination of Sulfate Content in CementISO 13195 Determination of Insoluble Residue in CementISO 13195 Determination of Insoluble Residue in CementISO 13195 Insoluble Residue Test in CementISO 13196 Determination of Loss on Ignition in CementISO 13196 Determination of Loss on Ignition in CementISO 14001 Environmental Management in Cement ManufacturingISO 14001 Environmental Management Systems in Lime ProductionISO 1920-3 Sampling Fresh ConcreteISO 29581-1 Cement Composition and Conformity - Part 1ISO 29581-2 Cement Composition and ConformityISO 679 Methods of Testing Cement – Determination of StrengthISO 9001 Quality Management in Cement ProductionISO 9001 Quality Management Systems in Cement ManufacturingJIS R 5201 Testing Methods for CementJIS R 5202 Chemical Analysis of CementJIS R 5205 Physical Testing of CementJIS R 5210 Physical Testing of LimeJIS R 5211 Chemical Analysis of Lime

Comprehensive Guide to EN 459-2 Test Methods for Building Lime Testing Services by Eurolab

EN 459-2 is a European standard that specifies the test methods for building lime, which is a crucial material used in construction. The standard is published by the European Committee for Standardization (CEN) and is part of the EN 459 series of standards. Building lime is a complex material that requires careful testing to ensure its quality and performance.

The legal and regulatory framework surrounding this testing service is governed by various international and national standards, including:

  • ISO 9001:2015 (Quality Management System)
  • ISO/IEC 17025:2017 (Competence of Testing and Calibration Laboratories)
  • EN 45011:2008 (General Criteria for the Accreditation of Testing Laboratories)
  • EU Regulation 305/2011 (New Legislative Framework for Machinery)
  • The international standards that apply to this specific laboratory test include:

  • ISO 9276-3:2014 (Calculation of particle size distribution from sedimentation experiments - Part 3: Standardisation and evaluation of the results of measurement of sediments in liquids)
  • ISO 4042:2009 (Cement. Test methods. Determination of setting times)
  • The national standards that apply to this specific laboratory test include:

  • TSE EN 459-2:2017 (Building lime. Test methods. Part 2: Determination of the reactivity and setting time)
  • ASTM C471-14 (Standard Test Methods for Chemical Analysis of Limestone Whetstone, and Paving Stone)
  • Eurolab is a testing laboratory that provides EN 459-2 test services to ensure the quality and performance of building lime.

    EN 459-2 test methods are required to ensure the quality and performance of building lime. The standard specifies various test methods, including:

  • Determination of reactivity
  • Determination of setting time
  • Determination of pH value
  • Determination of density
  • The industries that require this testing include construction, manufacturing, and research and development.

    Consequences of not performing this test can be severe, including:

  • Poor quality building lime
  • Reduced performance of building lime
  • Safety risks for users and consumers
  • Non-compliance with regulations and standards
  • The EN 459-2 test methods are conducted in accordance with the following conditions:

  • Temperature: 20 5 C
  • Humidity: 50 10
  • Pressure: 101.3 kPa
  • Sample preparation: Building lime samples must be prepared according to the standard.
  • The testing equipment and instruments used include:

  • pH meter
  • Density meter
  • Setting time apparatus
  • The sample preparation procedures involve:

  • Mixing of building lime with water
  • Measuring of reactivity and setting time
  • Determination of pH value and density
  • The measurement and analysis methods involve:

  • Calculation of reactivity and setting time
  • Measurement of pH value and density
  • Statistical analysis of results.
  • The calibration and validation procedures are conducted to ensure the accuracy and reliability of the test results.

    The test report is prepared in accordance with the standard, which includes:

  • Identification of building lime sample
  • Test methods used
  • Results of testing
  • Conclusion and recommendations
  • The report format and structure are as follows:

  • Cover page: Including identification of building lime sample and laboratory details
  • Introduction: Brief overview of testing and test methods used
  • Test results: Results of testing, including reactivity and setting time
  • Conclusion: Summary of results and conclusions
  • EN 459-2 test methods are essential to ensure the quality and performance of building lime. The benefits of this testing include:

  • Improved product safety and reliability
  • Compliance with regulations and standards
  • Quality assurance and control
  • Reduced risk of non-compliance
  • Enhanced customer confidence and trust
  • The competitive advantages of having this testing performed include:

  • Market positioning and differentiation
  • Innovation and research development support
  • Environmental and sustainability considerations
  • Eurolab is a leading testing laboratory that provides EN 459-2 test services to ensure the quality and performance of building lime. The benefits of choosing Eurolab include:

  • Expertise and experience in this field
  • State-of-the-art equipment and facilities
  • Qualified and certified personnel
  • International recognition and partnerships
  • Quality management systems and procedures
  • Eurolabs capabilities and advantages include:

  • Turnaround time and efficiency advantages
  • Competitive pricing and value proposition
  • Technical support and consultation services
  • Additional Requirements

  • Use professional and technical language appropriate for laboratory testing.
  • Include relevant technical specifications and parameters.
  • Provide examples of test results and conclusions.
  • Need help or have a question?
    Contact us for prompt assistance and solutions.

    Latest News

    View all

    JOIN US
    Want to make a difference?

    Careers