Heavy Metal Release & Elemental Testing ASTM D3223 Total Metals in Sediments and PackagingASTM D3644 Mercury in Soil and PackagingASTM D3867 Lead Content in Food Contact SurfacesASTM D4056 Compatibility Testing for MetalsASTM D4276 Heavy Metal Analysis in PackagingASTM D4276 Heavy Metals in Environmental SamplesASTM D4647 Total Mercury in Packaging MaterialsASTM D4773 Lead in Paints and Coatings for Food ContactASTM D5223 Heavy Metal Content in Paints and InksASTM D5223 Heavy Metals in Paints and PackagingASTM D5698 Determination of Metal Release from Food PackagingASTM D6940 Heavy Metals Testing in SoilASTM F1308 Heavy Metal Migration Testing in PolymersASTM F2023 Heavy Metal Migration TestingASTM F2257 Metal Migration in Plastic FilmsEN 1186-3 Specific Migration Testing for Heavy MetalsEN 1186-5 Testing of Plastics for Metal ReleaseEN 1186-7 Testing of Plastics for Heavy MetalsEN 12392 Determination of Lead in Drinking Water ContactEN 12392 Lead Testing in Packaging MaterialsEN 12457-4 Leaching Tests for Heavy MetalsEN 13130 Heavy Metal Testing in Food Contact PlasticsEN 13130-1 Migration Testing of PlasticsEN 13657 Heavy Metal Release TestingEN 13657 Heavy Metal Testing in Cosmetics PackagingEN 13657 Heavy Metal Testing in Packaging MaterialsEN 15290 Heavy Metals in Sewage Sludge PackagingEN 15763 Heavy Metals in Animal Feed PackagingEN 15763 Heavy Metals in Feed PackagingEN 15763 Heavy Metals in Plastic Food Contact MaterialsEPA 200.7 ICP-AES Analysis for MetalsEPA 200.8 ICP-MS for Trace MetalsEPA 200.9 ICP-AES Metal AnalysisEPA 3050B Acid Digestion of Packaging SamplesEPA 3051A Acid Digestion of Packaging SamplesEPA 3052 Microwave Assisted Acid Digestion for MetalsEPA 6010C ICP-AES Analysis for Metal ReleaseEPA 6010D ICP-AES for Heavy MetalsEPA 6020B ICP-MS for Metals in PackagingEPA 7196A Colorimetric Chromium DeterminationEPA 7199 Chromium VI DeterminationEPA 7421 Hydride Generation for Arsenic AnalysisEPA 7471B Mercury Analysis in Packaging MaterialsEPA 7473 Mercury Analysis in PackagingEPA Method 6020A Elemental Analysis by ICP-MSISO 11047 Soil Quality - Heavy Metals TestingISO 1186-2 Migration Testing of Polymeric MaterialsISO 11885 Determination of Metals in Water ContactISO 11885 ICP-OES Determination of Heavy MetalsISO 11885 ICP-OES Determination of MetalsISO 11885 ICP-OES Determination of Metals in PackagingISO 11885 ICP-OES Metal Analysis in PackagingISO 15192 Ceramic Material Heavy Metal ReleaseISO 15192 Release of Elements from Ceramic MaterialsISO 15371 Testing of Plastics for Metal ReleaseISO 15786 Release Testing of Food Contact MaterialsISO 16140 Validation of Heavy Metal Testing MethodsISO 16179 Determination of Heavy Metals in Soil PackagingISO 16620-1 Overall Migration and Metal ReleaseISO 17025 Heavy Metal Release Testing in Food Contact MaterialsISO 17072 Heavy Metal Release from PlasticsISO 17294-1 ICP-MS Determination of Trace ElementsISO 17294-2 ICP-MS Determination of Trace ElementsISO 17516 Microbial Limits and Metal ContaminationISO 21424 Heavy Metal Release in Cosmetics PackagingISO 21424 Heavy Metal Testing in Cosmetic PackagingISO 22000 Heavy Metal Risk Assessment in Food PackagingISO 22000 Risk Analysis of Heavy Metal ReleaseISO 22005 Traceability of Heavy Metals in PackagingISO 22005 Traceability of Packaging MaterialsISO 22036 Extraction of Metals from PackagingISO 22036 Heavy Metal Extraction from Packaging MaterialsISO 22039 Heavy Metal Content in Packaging SubstancesISO 22412 Mercury in Seafood and Packaging TestingISO 22514 Statistical Methods for Heavy Metal TestingISO 23317 Mercury Determination in Food Contact Materials

EPA 7473 Mercury in Solids and Packaging Materials Laboratory Testing Service: A Comprehensive Guide

As the global economy continues to grow, industries are increasingly subject to stringent regulations aimed at ensuring product safety and environmental protection. Among these regulations is the EPA 7473 standard for testing mercury in solids and packaging materials. This comprehensive guide provides a detailed overview of the standard, its requirements, and the benefits of performing this test through Eurolabs laboratory services.

Overview of Relevant Standards

The EPA 7473 standard is a regulatory framework established by the United States Environmental Protection Agency (EPA) to ensure the safe handling and disposal of mercury-containing products. This standard applies to various industries, including manufacturing, packaging, and waste management.

International Standards

  • ISO 11095:2012 - Mercury analysis in solid materials using cold-vapour atomic absorption spectrometry (CVAAS)
  • ASTM D7429-11 - Standard Test Method for Determination of Total Mercury in Solid Materials by Cold Vapour Atomic Absorption Spectroscopy
  • EN 14205:2006 - Testing of waste and recyclable materials. Sampling, sample preparation and storage. Part 1: General guidelines
  • National Standards

  • TSE (Turkish Standard Institution) TS 12766 - Determination of mercury in solid materials by cold-vapour atomic absorption spectrometry
  • Other national standards may apply depending on the country or region.
  • Development of Standards

    Standards are developed and updated through a collaborative effort between industry experts, regulatory bodies, and testing organizations. The development process typically involves:

    1. Identification of needs and gaps in existing standards.

    2. Formation of technical committees to draft new or revised standards.

    3. Public review and comment periods.

    4. Finalization and publication of the standard.

    Eurolabs Compliance with Standards

    Eurolab is committed to complying with all relevant national and international standards related to EPA 7473 testing. Our laboratory services ensure that tests are conducted in accordance with the latest revisions of these standards, guaranteeing accurate and reliable results.

    Legal and Regulatory Framework

    The EPA 7473 standard is a regulatory requirement for industries handling or disposing of mercury-containing products. Failure to comply can result in fines, penalties, and damage to reputation.

    Industries Affected

  • Manufacturing
  • Packaging
  • Waste management
  • Recycling
  • Why This Test Should Be Performed

    Performing EPA 7473 testing ensures compliance with regulations, protects the environment, and maintains public safety. The benefits of this test include:

    1. Risk assessment and mitigation.

    2. Quality assurance and compliance.

    3. Competitive advantages and market positioning.

    4. Cost savings and efficiency improvements.

    5. Legal and regulatory compliance.

    Why EPA 7473 Testing is Required

    EPA 7473 testing is necessary to ensure that products containing mercury are handled and disposed of safely. This test helps prevent environmental pollution, protects public health, and maintains industry reputation.

    Technical Reasons for Conducting the Test

    Mercury is a toxic substance that can have severe environmental and health impacts if not properly managed. EPA 7473 testing ensures that industries handle mercury-containing products responsibly.

    Consequences of Not Performing the Test

    Failure to conduct EPA 7473 testing can result in:

    1. Regulatory non-compliance.

    2. Environmental pollution.

    3. Public health risks.

    4. Damage to industry reputation.

    Industries and Sectors That Require Testing

    The following industries and sectors require EPA 7473 testing:

  • Manufacturing
  • Packaging
  • Waste management
  • Recycling
  • Risk Factors and Safety Implications

    EPA 7473 testing helps mitigate the risk of mercury release into the environment, protecting public health and safety.

    Quality Assurance and Control Aspects

    Eurolabs laboratory services ensure that EPA 7473 testing is performed with high accuracy and precision, maintaining quality assurance and control standards.

    Sample Preparation Procedures

    Sample preparation involves:

    1. Collection of representative samples.

    2. Weighing and homogenization of samples.

    3. Preparation for analysis.

    Testing Parameters and Conditions

    EPA 7473 testing is conducted using the following parameters and conditions:

  • Instrumentation: Cold-vapour atomic absorption spectrometry (CVAAS)
  • Sample size: Typically 0.5-1 gram
  • Sampling frequency: Typically once per year or as required by regulations
  • Measurement and Analysis Methods

    EPA 7473 testing involves measurement of mercury concentration using CVAAS.

    Calibration and Validation Procedures

    Eurolabs laboratory services ensure that equipment is calibrated and validated regularly to maintain accuracy and precision.

    Quality Control Measures During Testing

    Quality control measures include:

    1. Use of certified reference materials.

    2. Regular instrument calibration and validation.

    3. Data review and verification.

    Test Results and Reporting

    Test results are reported in accordance with EPA 7473 requirements, providing clear and concise information on mercury concentration levels.

    Why Choose Eurolab for EPA 7473 Testing?

    Eurolab offers a comprehensive range of laboratory services, including EPA 7473 testing. Our experts ensure that tests are conducted accurately and efficiently, providing reliable results and supporting industry compliance with regulations.

    ---

    This comprehensive guide provides an in-depth overview of the EPA 7473 standard, its requirements, and the benefits of performing this test through Eurolabs laboratory services. If you have any questions or require further information on our laboratory services, please do not hesitate to contact us.

    Need help or have a question?
    Contact us for prompt assistance and solutions.

    Latest News

    View all

    JOIN US
    Want to make a difference?

    Careers