EUROLAB
astm-d3370-determination-of-total-organic-halogens-in-water
Potable Water Microbiological & Chemical Analysis APHA 2540 Total Dissolved Solids (TDS) Testing in WaterAPHA 4500-H+ pH Measurement of Drinking WaterAPHA 9221 Multiple-Tube Fermentation Technique for ColiformsASTM D1067 Acidity and Alkalinity Testing in Water SamplesASTM D1125 Electrical Conductivity Measurement of WaterASTM D1126 Standard Test Method for Turbidity of WaterASTM D1253 Residual Chlorine Testing in Water SamplesASTM D1783 Determination of Nitrate in WaterASTM D1946 Gas Chromatography of Volatile Organic Compounds in WaterASTM D2216 Moisture Content of Soil and RockASTM D2974 Moisture, Ash, and Organic Matter of Sludge by Loss on IgnitionASTM D3559 Determination of Total Phosphorus in WaterASTM D3867 Nitrite and Nitrate Analysis in Potable WaterASTM D512 Chloride Concentration Testing in Water SamplesASTM D512 Total Chloride Ion Determination by TitrationASTM D516-89 Determination of Cyanide in WaterASTM D5176 Measurement of Alkalinity in WaterEN 1622 Chlorine Odor and Taste Testing in Drinking WaterEN 26777 Nitrite Content Analysis in Potable WaterEN ISO 10304-1 Ion Chromatography for Anions in Potable WaterEN ISO 10304-3 Determination of Dissolved Anions by Ion ChromatographyEN ISO 10523 pH Measurement of Water QualityEN ISO 11256 Determination of Total Chromium in WaterEN ISO 11369 Cyanide Content Analysis in Water SamplesEN ISO 11732 Ammonium Testing in Drinking Water via FIAEN ISO 11732 Determination of Ammonium in Water by Flow AnalysisEN ISO 11885 Inductively Coupled Plasma for Metal Analysis in WaterEN ISO 11901 Determination of Bromide in Water SamplesEN ISO 11905-1 Nitrogen Analysis via Devarda’s Method in WaterEN ISO 11905-2 Determination of Nitrogen in Water SamplesEN ISO 14403 Determination of Pesticides in Water by GC-MSEN ISO 5663 Guidelines for Sample Preparation of Water TestingEN ISO 5667-1 Guidance on Sampling Water QualityEN ISO 5667-17 Guidance on Sampling for Particles in WaterEN ISO 5667-21 Sampling of Sediments for Chemical AnalysisEN ISO 7027 Turbidity Testing of Drinking Water SamplesEN ISO 7393-1 Chlorine Quantification Using Titrimetry in WaterEN ISO 7393-2 Free and Total Chlorine Analysis in Drinking WaterEN ISO 7887 Color Determination in Potable Water SamplesEN ISO 8466-1 Water Quality – Determination of pHEN ISO 8467 Permanganate Index Testing in Drinking WaterEPA 110.3 Determination of Phenols in WaterEPA 1604 Enterococci Bacteria Detection in Drinking WaterEPA 1664 Measurement of Oil and Grease in WaterEPA 200.1 Inductively Coupled Plasma-Atomic Emission SpectrometryEPA 200.7 Trace Metal Determination in Drinking Water by ICP-AESEPA 200.8 Trace Elements in Drinking Water Using ICP-MSEPA 200.9 Trace Elements Determination by GFAAS in Drinking WaterEPA 300.0 Inorganic Anions Determination by Ion ChromatographyEPA 300.1 Anions Analysis Including Fluoride and Nitrate in WaterEPA 300.1 Determination of Chloride in Drinking WaterEPA 300.2 Determination of Sulfate in WaterEPA 335.4 Cyanide Measurement in Drinking Water SamplesEPA 350.1 Determination of Chemical Oxygen Demand (COD)EPA 350.2 Measurement of Total Organic Carbon in WaterEPA 353.2 Nitrate-Nitrite Testing in Potable Water SamplesEPA 365.2 Determination of Phenolic Compounds in WaterEPA 410.4 Analysis of Cyanide in Water SamplesEPA 505 Organochlorine Pesticides Analysis in Potable WaterEPA 524.2 Purgeable Organic Compounds Testing in Water SamplesEPA 524.3 VOC Analysis in Potable Water Using GC/MSEPA 524.4 Measurement of Disinfection Byproducts in WaterEPA 531.2 Carbamate Pesticides Detection in Drinking WaterEPA 551.1 Determination of Carbon Tetrachloride in Drinking WaterEPA 552.3 Haloacetic Acids Testing in Potable WaterEPA 600/4-79-020 Colorimetric Analysis of OrthophosphateEPA 600/4-80/014 Chlorophyll-a Determination in WaterEPA 601 Method for Determination of Polychlorinated Biphenyls (PCBs)EPA 608 Pesticides and PCBs Testing in Drinking Water SamplesEPA 608 Pesticides and PCBs Testing in Drinking Water SamplesEPA 625 Methods for Volatile Organic Compounds Analysis in WaterEPA 815-B-17-015 Cryptosporidium and Giardia Detection in WaterEPA 8270 Semi-Volatile Organic Compounds Analysis in WaterEPA 906.0 Determination of Mercury in Water by Cold Vapor Atomic AbsorptionEPA 906.0 Mercury Analysis by Cold Vapor Atomic AbsorptionEPA 906.0 Mercury Determination by CVAASIS 10500 Fluoride Level Compliance Testing in Potable WaterIS 10500 Nitrate Level Analysis in Drinking WaterIS 3025 Part 34 Phenolic Compounds Testing in Potable WaterISO 10530 Measurement of Turbidity in Water SamplesISO 11369 Cyanide Determination in WaterISO 15586 Atomic Absorption for Mercury Detection in WaterISO 15680 VOC Detection by Purge and Trap GC/MS in WaterISO 15681 Determination of Polychlorinated Biphenyls (PCBs) in WaterISO 15705 Determination of Total Organic Carbon in WaterISO 15705 Measurement of Total Organic Carbon (TOC) in WaterISO 16265 Trihalomethane Concentration Testing in Drinking WaterISO 17993 Determination of Mercury in Water by CVAASISO 5667-10 Sampling of WastewatersISO 5667-13 Guidance on Sampling for Cyanobacteria and AlgaeISO 5667-14 Guidance on Sampling for Microorganisms in WaterISO 5667-15 Guidance on Sampling for Metals in WaterISO 5667-18 Guidance on Sampling for Volatile Organic CompoundsISO 5667-19 Guidance on Sampling for Trace ElementsISO 5667-2 Guidance on Sampling StrategiesISO 5667-20 Guidance on Sampling for Microcystins and Other CyanotoxinsISO 5667-3 Sampling Protocols for Microbiological Water TestingISO 5667-4 Guidance on Sampling Preservation and HandlingISO 5667-5 Sampling Strategy for Drinking Water AnalysisISO 5667-6 Water Sampling – Guidance on Sampling TechniquesISO 7028 Sampling of Water for Chemical and Microbiological TestingISO 7887 Water Sample Color Measurement for Quality ControlISO 7888 Electrical Conductivity Testing of Drinking WaterISO 9308-1 E. coli and Coliform Bacteria Testing in Drinking WaterISO 9963-1 Determination of Carbon Dioxide in WaterWHO Guidelines-Based Lead Content Testing in Potable Water

ASTM D3370 Determination of Total Organic Halogens in Water: Eurolabs Laboratory Testing Service

The determination of total organic halogens (TOH) in water is a critical aspect of ensuring the safety and quality of drinking water. The American Society for Testing and Materials (ASTM) has established standard D3370 to provide guidelines for this testing procedure.

Relevant Standards and Regulations

  • ASTM D3370: This standard provides the method for determining the total organic halogen content in water.
  • ISO 16918: This international standard is based on ASTM D3370 and provides a similar method for determining TOH in water.
  • EN 1484: This European standard also addresses the determination of TOH in water, although it has some differences from ASTM D3370.
  • Legal and Regulatory Framework

    The legal and regulatory framework surrounding TOH testing in water is primarily driven by environmental regulations. In many countries, including the United States, the European Union, and Canada, there are strict guidelines for drinking water quality, which include limits on TOH concentrations.

  • Safe Drinking Water Act (SDWA): In the United States, the SDWA sets standards for drinking water quality, including maximum allowable levels of TOH.
  • European Unions Drinking Water Directive: This directive establishes a framework for ensuring the safety and quality of drinking water across EU member states.
  • Standard Development Organizations

    Standard development organizations (SDOs) play a crucial role in establishing and maintaining standards like ASTM D3370. SDOs ensure that standards are developed through a collaborative effort involving industry experts, regulators, and other stakeholders.

  • ASTM International: As the developer of standard D3370, ASTM International has established guidelines for TOH testing in water.
  • International Organization for Standardization (ISO): ISO is responsible for developing international standards based on existing national standards, such as ASTM D3370.
  • Evolution and Updates

    Standards like ASTM D3370 are not static documents. They undergo regular review and updates to reflect new scientific knowledge, advances in technology, and changing regulatory requirements.

  • Revision History: The latest revision of ASTM D3370 was published in 2022, incorporating updates based on new research and data.
  • Balloting Process: When a standard is revised or updated, it undergoes a balloting process involving members of the relevant technical committee to ensure that changes are acceptable to all stakeholders.
  • Standard Compliance Requirements

    Compliance with standards like ASTM D3370 is essential for industries involved in water treatment, testing, and distribution. Failure to comply can result in fines, penalties, or even legal action.

  • Drinking Water Utilities: These utilities must ensure that their drinking water meets the TOH limits established by regulatory agencies.
  • Water Treatment Plants: These plants must implement processes to remove TOH from water before it is distributed for consumption.
  • The determination of TOH in water is a critical aspect of ensuring the safety and quality of drinking water. The testing process involves various steps, including sample collection, preparation, analysis, and reporting.

    Business and Technical Reasons for Testing

    Testing for TOH in water is essential for several reasons:

  • Regulatory Compliance: Water utilities must ensure that their drinking water meets regulatory limits for TOH.
  • Product Safety: Water treatment plants must implement processes to remove TOH from water before it is distributed for consumption.
  • Environmental Protection: Excessive levels of TOH in water can harm aquatic ecosystems and human health.
  • Consequences of Not Performing the Test

    Failure to test for TOH in water can result in:

  • Non-Compliance with Regulations: Fines, penalties, or even legal action may be imposed on utilities that fail to comply with regulatory limits.
  • Product Safety Risks: Water treatment plants may not effectively remove TOH from water, posing a risk to human health and the environment.
  • Environmental Damage: Excessive levels of TOH in water can harm aquatic ecosystems.
  • Industries and Sectors That Require Testing

    The following industries and sectors require testing for TOH in water:

  • Drinking Water Utilities: These utilities must ensure that their drinking water meets regulatory limits for TOH.
  • Water Treatment Plants: These plants must implement processes to remove TOH from water before it is distributed for consumption.
  • Environmental Monitoring Agencies: These agencies monitor water quality, including TOH levels.
  • Quality Assurance and Control

    To ensure accurate results, laboratories involved in testing for TOH in water must follow strict quality assurance and control protocols:

  • Sample Handling and Storage: Samples must be handled and stored properly to prevent contamination or degradation.
  • Instrument Calibration and Maintenance: Testing equipment must be calibrated regularly and maintained according to the manufacturers instructions.
  • The testing procedure for TOH in water involves several steps:

    Sample Collection

    Samples are collected from various sources, including drinking water distribution systems, wastewater treatment plants, or surface waters.

  • Sample Containers: Samples must be stored in containers that prevent contamination and degradation.
  • Transportation and Storage: Samples must be transported and stored properly to maintain their integrity.
  • Preparation

    Samples are prepared for analysis by adjusting their pH, diluting them as necessary, and removing any interfering substances.

  • pH Adjustment: The pH of the sample is adjusted to a level that minimizes interference with the analysis.
  • Dilution: Samples may be diluted to concentrations within the analytical range.
  • Analysis

    The TOH content in water is determined using various analytical techniques, including:

  • Ion Chromatography (IC): IC separates and detects anions in water, including halides.
  • Chromatography-Mass Spectrometry (MS): MS identifies and quantifies the mass-to-charge ratio of ions in water.
  • Reporting

    Results are reported in units of milligrams per liter (mg/L) or parts per billion (ppb).

  • Data Quality Objectives: Laboratories must ensure that their data quality objectives meet regulatory requirements.
  • Certification and Accreditation: Laboratories involved in testing for TOH in water must be certified and accredited by recognized accrediting bodies.
  • Limitations of the Testing Method

    The testing method for TOH in water has some limitations:

  • Interference from Other Substances: Certain substances can interfere with the analysis, leading to inaccurate results.
  • Sample Contamination: Samples can become contaminated during collection, transportation, or storage.
  • To ensure accurate results, laboratories involved in testing for TOH in water must follow strict quality control and quality assurance protocols:

    Sample Handling and Storage

    Samples must be handled and stored properly to prevent contamination or degradation.

  • Sample Containers: Samples must be stored in containers that prevent contamination and degradation.
  • Transportation and Storage: Samples must be transported and stored properly to maintain their integrity.
  • Instrument Calibration and Maintenance

    Testing equipment must be calibrated regularly and maintained according to the manufacturers instructions.

  • Calibration Schedule: Equipment must be calibrated at regular intervals, such as every six months or after a certain number of analyses.
  • Maintenance Schedule: Equipment must be serviced regularly to ensure optimal performance.
  • Quality Control Measures

    Laboratories involved in testing for TOH in water must implement quality control measures to ensure accurate results:

  • Blank Samples: Laboratories must analyze blank samples to detect any contamination during the analysis process.
  • Spiking Studies: Laboratories must perform spiking studies to evaluate the accuracy and precision of their analytical methods.
  • Quality Assurance Measures

    Laboratories involved in testing for TOH in water must implement quality assurance measures to ensure accurate results:

  • Internal Audit Program: Laboratories must have an internal audit program to evaluate their quality control procedures.
  • Continuing Education: Laboratory personnel must receive regular continuing education to stay up-to-date with new analytical techniques and methodologies.
  • Conclusion

    The determination of TOH in water is a critical aspect of ensuring the safety and quality of drinking water. The testing process involves various steps, including sample collection, preparation, analysis, and reporting. Laboratories involved in testing for TOH in water must follow strict quality control and quality assurance protocols to ensure accurate results. Failure to comply with regulatory limits can result in fines, penalties, or even legal action.

    References

  • ASTM D3370: Standard Test Method for Total Organic Halogen (TOX) Content of Water.
  • ISO 16918: International Standard - Drinking water - Determination of total organic halogens (TOH).
  • EN 1484: European Standard - Drinking water - Determination of total organic halogens (TOH).
  • Appendix

    The following appendix provides additional information on the testing procedure for TOH in water:

    Testing Method

    The testing method for TOH in water involves several steps:

    1. Sample collection: Samples are collected from various sources, including drinking water distribution systems, wastewater treatment plants, or surface waters.

    2. Preparation: Samples are prepared for analysis by adjusting their pH, diluting them as necessary, and removing any interfering substances.

    3. Analysis: The TOH content in water is determined using various analytical techniques, including ion chromatography (IC) and chromatography-mass spectrometry (MS).

    4. Reporting: Results are reported in units of milligrams per liter (mg/L) or parts per billion (ppb).

    Quality Control Measures

    Laboratories involved in testing for TOH in water must implement quality control measures to ensure accurate results:

  • Blank samples: Laboratories must analyze blank samples to detect any contamination during the analysis process.
  • Spiking studies: Laboratories must perform spiking studies to evaluate the accuracy and precision of their analytical methods.