EUROLAB
iec-61000-4-11-voltage-dips-short-interruptions-and-voltage-variations-test
EMC (Electromagnetic Compatibility) Testing ANSI C63.4 Methods of Measurement of Radio-Noise EmissionsCISPR 11 Industrial Equipment EmissionsCISPR 11 Industrial, Scientific and Medical (ISM) Equipment EmissionsCISPR 12 Limits for the Protection of Receivers in the Frequency Range 150 kHz to 108 MHz in VehiclesCISPR 13 Radio Disturbance for Broadcast ReceiversCISPR 14-1 Emission Requirements for Household AppliancesCISPR 14-2 Immunity Requirements for Household AppliancesCISPR 14-3 Emission Testing for Household AppliancesCISPR 15 Limits for Lighting Equipment EmissionsCISPR 15 Limits for Radio Disturbance from Lighting EquipmentCISPR 15 Radio Disturbance from Lighting EquipmentCISPR 16 Measurement Techniques for EMC TestingCISPR 16 Specification for Radio Disturbance and Immunity Measuring ApparatusCISPR 21 Limits for Protection of Receivers in Broadcast BandsCISPR 21 Receiver Protection Against InterferenceCISPR 22 Radiated and Conducted Emission Test for IT EquipmentCISPR 22 Radio Disturbance Characteristics for IT EquipmentCISPR 24 Immunity Requirements for Information Technology EquipmentCISPR 25 Radio Disturbance Characteristics for the Protection of Receivers in VehiclesCISPR 25 Vehicle Components Radio Disturbance TestingCISPR 32 Electromagnetic Compatibility of Multimedia EquipmentCISPR 32 EMC for Multimedia EquipmentCISPR 32 Multimedia Equipment Emission and ImmunityCISPR 34 Emission Requirements for Audio EquipmentEN 50121-1 EMC Requirements for Railway InfrastructureEN 50121-2 Railway EMC for Trackside EquipmentEN 50121-3-2 Railway Applications - EMC of Rolling StockEN 50121-4 EMC of Signalling and Telecommunications EquipmentEN 50130-4 Alarm Systems EMC RequirementsEN 50130-5 Alarm Systems - EMC Requirements for ComponentsEN 50155 Electronic Equipment on Railway Vehicles - EMCEN 50155 Railway Rolling Stock EMC TestingEN 50270 EMC for Alarm SystemsEN 50561-1 EMC Requirements for Power Line Communication EquipmentEN 50581 Compliance Documentation for RoHSEN 50581 Technical Documentation for the Assessment of Electrical and Electronic EquipmentEN 55014-1 Emission Requirements for Household AppliancesEN 55014-1 Household Appliance Emission TestingEN 55014-2 Immunity Requirements for Household AppliancesEN 55015 Limits and Methods of Measurement of Radio Disturbance from Lighting EquipmentEN 55020 Immunity Characteristics for Broadcast ReceiversEN 55022 Class B Emission Compliance TestingEN 55022 Information Technology Equipment - Radio Disturbance CharacteristicsEN 55022 Information Technology Equipment Emission TestingEN 55024 Immunity Requirements for IT EquipmentEN 55024 Information Technology Immunity TestingEN 55025 Vehicle Components EMC RequirementsEN 55025 Vehicle EMC Immunity TestingEN 55032 Emission Requirements for Multimedia EquipmentEN 55032 Emission Requirements for Multimedia EquipmentEN 55035 Immunity Requirements for Multimedia EquipmentEN 55035 Immunity Testing for Multimedia EquipmentEN 55035 Multimedia Equipment Immunity RequirementsEN 61000-3-11 Limitation of Voltage Fluctuations and Flicker in Public Low-Voltage Supply SystemsEN 61000-3-12 Limits for Voltage Changes and Flicker in Public Supply SystemsEN 61000-6-1 Generic Immunity Standard for Residential, Commercial and Light-Industrial EnvironmentsEN 61000-6-2 Generic Immunity Standard for Industrial EnvironmentsEN 61000-6-3 Emission Standard for Residential EnvironmentsEN 61000-6-3 Generic Emission Standard for Residential, Commercial and Light-Industrial EnvironmentsEN 61000-6-4 Generic Emission Standard for Industrial EnvironmentsFCC Part 15 Intentional Radiator TestingFCC Part 15 Radio Frequency Devices Emission TestingFCC Part 15 Subpart B Unintentional Radiator Compliance TestingFCC Part 18 Industrial, Scientific and Medical Equipment EmissionsFCC Part 68 EMC Requirements for Telephone EquipmentIEC 60601-1-2 Medical Electrical Equipment EMC RequirementsIEC 61000-3-2 Harmonic Current Emissions TestIEC 61000-3-3 Voltage Flicker and Flicker Severity TestIEC 61000-4-10 Damped Oscillatory Magnetic Field Immunity TestIEC 61000-4-12 Ring Wave Immunity TestIEC 61000-4-13 Harmonic Current Immunity TestIEC 61000-4-14 Voltage Fluctuations Immunity TestIEC 61000-4-16 Conducted Immunity TestingIEC 61000-4-17 Ripple on DC Input Power Ports Immunity TestIEC 61000-4-18 Burst Immunity Test in Industrial EnvironmentsIEC 61000-4-19 Testing of Power Quality Parameters in TelecommunicationsIEC 61000-4-2 Electrostatic Discharge Immunity TestIEC 61000-4-21 Testing of Power Quality DisturbancesIEC 61000-4-23 Damped Oscillatory Magnetic Field TestIEC 61000-4-24 Testing of DC Input Ports ImmunityIEC 61000-4-25 Voltage Dips, Short Interruptions ImmunityIEC 61000-4-26 Immunity to Voltage FluctuationsIEC 61000-4-27 Conducted Immunity Testing for RailwaysIEC 61000-4-28 Voltage Dips and Interruptions Immunity TestingIEC 61000-4-29 Voltage Dips, Short Interruptions and Voltage Variations ImmunityIEC 61000-4-3 Radiated Radio-Frequency Electromagnetic Field Immunity TestIEC 61000-4-30 Power Quality Measurement MethodsIEC 61000-4-31 Radiated Immunity Test Using Bulk Current InjectionIEC 61000-4-32 Testing of Power Quality ParametersIEC 61000-4-33 Immunity to Conducted Disturbances Induced by Radio-Frequency FieldsIEC 61000-4-34 Damped Oscillatory Transient Immunity TestIEC 61000-4-35 Power Quality Measurement TechniquesIEC 61000-4-36 High Frequency Conducted Disturbances Immunity TestIEC 61000-4-37 Immunity to Voltage Dips and InterruptionsIEC 61000-4-38 Conducted Immunity at Telecom PortsIEC 61000-4-4 Electrical Fast Transient/Burst Immunity TestIEC 61000-4-40 Electrostatic Discharge Immunity for Household AppliancesIEC 61000-4-41 Power Quality Measurement - Harmonics and InterharmonicsIEC 61000-4-42 Immunity to Electromagnetic Disturbances in Power NetworksIEC 61000-4-43 Testing of Conducted EmissionsIEC 61000-4-44 Immunity Tests for RailwaysIEC 61000-4-45 Damped Oscillatory Immunity TestIEC 61000-4-46 Testing Immunity to Conducted DisturbancesIEC 61000-4-47 Immunity to HarmonicsIEC 61000-4-49 Power Quality Harmonics and Interharmonics MeasurementIEC 61000-4-5 Surge Immunity TestIEC 61000-4-50 Testing Immunity to Voltage FluctuationsIEC 61000-4-51 Measurement of Radiated EmissionsIEC 61000-4-52 Bulk Current Injection Test MethodIEC 61000-4-53 Immunity to Conducted Disturbances Induced by Radio-Frequency FieldsIEC 61000-4-54 Power Frequency Magnetic Field ImmunityIEC 61000-4-6 Conducted Radio-Frequency Immunity TestIEC 61000-4-7 Measurement of Power Quality ParametersIEC 61000-4-8 Power Frequency Magnetic Field Immunity TestIEC 61000-4-9 Pulse Magnetic Field Immunity TestIEC 61800-3 EMC Requirements for Adjustable Speed Electrical Power Drive SystemsISO 7637 Road Vehicles Electrical Transient Conduction Along Supply LinesMIL-STD-461 Electromagnetic Interference Requirements for Military Equipment

A Comprehensive Guide to IEC 61000-4-11 Voltage Dips, Short Interruptions and Voltage Variations Test Laboratory Testing Service Provided by Eurolab

IEC 61000-4-11 is a standard that defines the requirements for testing electrical equipment against voltage dips, short interruptions, and voltage variations. This standard is part of the IEC 61000 series, which deals with electromagnetic compatibility (EMC) testing.

Legal and Regulatory Framework

The legal and regulatory framework surrounding IEC 61000-4-11 testing varies by country. In Europe, for example, the EU Directives and Regulations, such as the Low Voltage Directive (LVD), require that electrical equipment meets specific EMC standards, including IEC 61000-4-11.

International and National Standards

IEC 61000-4-11 is an international standard published by the International Electrotechnical Commission (IEC). It is also adopted as a national standard in many countries, such as EN 61000-4-11 in Europe. Other relevant standards include:

  • IEC 60034-1: Rotating electrical machines
  • IEC 60335-1: Household and similar electrical appliances
  • IEC 61508: Functional safety of electrical/electronic/programmable electronic safety-related systems
  • Standard Development Organizations

    The development of IEC standards, including IEC 61000-4-11, is the responsibility of technical committees composed of experts from various countries. These technical committees review and update standards as needed to reflect changes in technology or regulatory requirements.

    Evolution of Standards

    Standards evolve over time to address new technologies, emerging risks, and changing regulatory requirements. For example, IEC 61000-4-11 has undergone several revisions since its initial publication in 2009.

    Standard Numbers and Scope

    IEC 61000-4-11 is a specific standard that deals with voltage dips, short interruptions, and voltage variations testing. The standard provides guidelines for testing electrical equipment under various types of voltage disturbances.

    Standard Number Title

    --- ---

    IEC 61000-4-11 Voltage Dips, Short Interruptions and Voltage Variations on Power Supply Port

    EN 61000-4-11 Voltage Dips, Short Interruptions and Voltage Variations on Power Supply Port

    Industry-Specific Requirements

    Different industries have varying requirements for IEC 61000-4-11 testing. For example:

  • Medical devices: IEC 60601-1-2
  • Industrial control equipment: IEC 61131-6
  • Electric vehicles: IEC 61851-1
  • Standard Compliance Requirements

    Compliance with IEC 61000-4-11 is mandatory for electrical equipment intended for use in specific environments, such as industrial or residential areas. Non-compliance can result in regulatory fines and damage to reputation.

    Standard-Related Risks

    Non-compliance with IEC 61000-4-11 can lead to a range of risks, including:

  • Electrical shocks
  • Fires
  • Equipment damage
  • System failures
  • Business and Technical Reasons for Conducting IEC 61000-4-11 Testing

    IEC 61000-4-11 testing is essential for ensuring the reliability and safety of electrical equipment. It helps manufacturers to:

  • Reduce warranty claims and liabilities
  • Enhance product reputation and customer confidence
  • Comply with regulatory requirements
  • Improve product performance and efficiency
  • Consequences of Not Performing IEC 61000-4-11 Testing

    Failure to conduct IEC 61000-4-11 testing can result in non-compliance, damage to reputation, and financial losses.

    Risk Factors and Safety Implications

    IEC 61000-4-11 testing helps manufacturers to identify potential risks associated with voltage dips, short interruptions, and voltage variations. These risks include:

  • Equipment failure
  • System crashes
  • Electrical shocks
  • Quality Assurance and Quality Control Aspects

    IEC 61000-4-11 testing is an essential component of a manufacturers quality assurance and quality control processes.

    Testing Equipment and Instruments

    The following equipment and instruments are used for IEC 61000-4-11 testing:

  • Power sources
  • Voltage regulators
  • Current transformers
  • Data acquisition systems
  • Testing Environment Requirements

    IEC 61000-4-11 testing is typically conducted in a controlled laboratory environment with specific temperature, humidity, and pressure conditions.

    Parameter Value

    --- ---

    Temperature 20C 2C

    Humidity 60 10

    Voltage Dips Testing

    IEC 61000-4-11 testing involves subjecting the equipment to various types of voltage dips, including:

  • Symmetrical and asymmetrical voltage dips
  • DC and AC voltage dips
  • Short Interruptions Testing

    IEC 61000-4-11 testing also involves simulating short interruptions on the power supply.

    Parameter Value

    --- ---

    Duration 100 ms to 1 s

    Frequency Up to 5 Hz

    Voltage Variations Testing

    IEC 61000-4-11 testing involves subjecting the equipment to various types of voltage variations, including:

  • Slow and fast voltage changes
  • DC and AC voltage variations
  • Data Acquisition and Analysis

    IEC 61000-4-11 testing involves collecting data on the equipments performance during testing.

    Parameter Value

    --- ---

    Sampling rate Up to 1 kHz

    Resolution 12-bit or higher

    Test Report Preparation

    The test report should include:

  • Equipment details
  • Test conditions
  • Results of testing
  • ---

    Conclusion

    IEC 61000-4-11 is a critical standard for ensuring the reliability and safety of electrical equipment. Manufacturers must comply with this standard to avoid regulatory fines, damage to reputation, and financial losses.

    At Eurolab, we provide comprehensive IEC 61000-4-11 testing services to help manufacturers ensure compliance with international standards. Our experienced engineers and state-of-the-art testing facilities enable us to deliver high-quality results in a timely manner.

    If you are interested in learning more about our IEC 61000-4-11 testing services, please contact us today!

    References

  • IEC 61000-4-11:2011
  • EN 61000-4-11:2011
  • IEC 60034-1:2009
  • IEC 60335-1:2009
  • Need help or have a question?
    Contact us for prompt assistance and solutions.

    Latest News

    View all

    JOIN US
    Want to make a difference?

    Careers